Description
Operation Recommendations: Supply unit with 100 PSI air pressure and 110 volt power. Turn on unit when the filling cycle begins and continue to operate unit 15 minutes after filling cycle is complete.
Dust Collector Specifications
Total Filtration Area: 330 Sq. Ft.
Air to Cloth Ratio (ACFM/Sq.’): 4.8
Pressure Drop: 6”
Air Capacity: 1600
Outlet Area (Sq.’): .83
Cleaning Method: Pulse Jet
Inlet Dust Concentration at 15 Gr./Cu’: 25,000
Outlet Emissions (Gr./Min): 2.50
Outlet Dust Loading (Gr./Cu.’): .0015
Air Consumption: 8 CFM
Solenoids: 3 w/ Timer Board
Filter Cartridge Specifications
Dimensions: (6) 10.09” OD x 5.75” ID x 30” height
Top End Cap: G60 Galvanized-Open with 11.000” Flange
Bottom End Cap: G60 Galvanized-Closed
Gasket: 5/8” Height x 10” ID Neoprene
Outline Retainer: Retainer Bands
Inner Core: Galvanized Expanded Metal, 72% Open
Filter Area: 55 Square Feet
Fiber: 100% Spun Bond Polyester
Material Weight: 8 oz / Square Yard
Permeability: 24 C.F.M.
Mullen Burst Dry: 388 PSI
Temperature Limit: 275 Degrees Fahrenheit
Efficiency: 99.99%
Instructions for Changing Filter Cartridges
- Remove the round cover on top of the dust collector.
- Loosen hold-down knobs for blower pipes.
- Loosen the (3) pipe unions and remove the blower pipes.
- Remove the filter cartridge holders.
- Remove the used filter cartridges.
- Install new filter cartridges and re-install the filter cartridge holders (make sure the cartridge is centered in the hole) tighten the nuts on the filter cartridge holders (do not overtighten).
- Re-install blower pipes and tighten the pipe unions (making sure the blower pipe nozzles are centered in the filter cartridge)
- Tighten the hold-down knobs for the blower pipes.
- Replace the round cover and secure with hold-down knobs.
- Inspect the filter cartridge monthly and replace every 6 to 12 months.
Reviews